제품 상세보기

  • Gencomm/RF Analyzer/GC7106A
  • Gencomm/RF Analyzer/GC7106A
  • Gencomm/RF Analyzer/GC7106A

Gencomm / RF Analyzer / GC7106A 
Frequency Accuracy ±0.05ppm Internal Frequency Aging ±0.5ppm/year Display 8.4"TFT LCD 800 x 600 mode Frequency and Time Reference Even Second TTL 10MHz,13MHz,15MHz -10 ~ +10 dBm Spectrum Analyzer Input Frequency Range 100kHz ~ 3GHz Maximum Input level +30dBm (1W) Amplitude Accuracy ± 1dB Resolution Bandwidth 100Hz ~ 1MHz (1-3 sequence) Video Bandwidth 1Hz ~ 1MHz (1-3 sequence) Dynamic Range >85dB Input Input Attenuation 0 ~ 50dB (Step: 5dB) SSB Phase Noise -95dBc/Hz @30KHz offset -105dBc/Hz @100KHz offset DANL Typical -140dBm @100Hz RBW with Preamp On Frequency Typical Max 10MHz ~ 1GHz -140dBm -142dBm 1GHz ~ 2GHz -138dBm -140dBm 2GHz ~ 3GHz -138dBm -138dBm Measurement Range DANL ~ +30dBm Port 1 VSWR < 1.5 Power Meter Frequency Range 100KHz ~ 3GHz Display ±100dBm (user settable) Measurement Range -70dBm ~ +30dBm Offset Range 0 ~ 60 dB Accuracy -40dBm ≤ Power ≤ +30dBm ±1.0dB -70dBm ≤ Power < -40dBm ±1.5dB VSWR < 1.5 Maximum Power +30dBm(1W) without external attenuator Antenna/Cable Frequency Range 25MHz ~ 4GHz Frequency Resolution 100KHz Data Point 126, 251, 501, 1001 Cable Loss Dynamic Range 0 ~ 30 dB Resolution 0.01dB VSWR VSWR Range 1 ~ 65 Return Loss 0 ~ 60dB Resolution 0.01 or 0.01dB DTF Distance 1250m (4125ft) Horizontal Range 0 to (# of data points-1) x (resolution-1)/2 Resolution (1.5x108)(VP)/(Delta)(ZF) Vp: Cable's relative propagation velocity Delta[Hz] = Stop Freq ? Start Freq ZF(Zoom Factor) = Setup Dist./Max Dist VSWR Range 1 ~ 65 Return Loss Range 0 ~ 60 dB Gain / Loss Measurement Frequency Ranget 25MHz ~ 4GHz Frequency Resolution 100KHz Output Power Level -10 dBm typical Dynamic Range 25MHz ~ 2GHz 80dB 2GHz ~ 4GHz 60dB High Accuracy Power Meter Display Range -80 ~ +80 dBm Offset Range 0 ~ +60 dB Resolution 0.01 dB or 0.1xW Directional Power Sensor (GC731A) Frequency Range 300 ~ 3800MHz Power Range Average Power: 0.15W ~ 150W Peak Power: 4 ~ 400W Measurement Uncertainty ±4% of reading Above 35ºC or Below 15 ºC add 3% Input VSWR 300 ~ 3000MHz < 1.07 3000 ~ 3800MHz < 1.10 RF Connector N Female Terminating Power Sensor (GC732A) Frequency Range 20 ~ 3800MHz Power Range Average Power: 1μW ~ 100mW Measurement Uncertainty ±7% Input VSWR 20 ~ 2500MHz < 1.12 2500 ~ 3800MHz < 1.125 RF Connector N Female External Reference Clock 10, 13, 15MHz External Reference Input Power -10 ~ +10dBm Connector Type SMA Even Second Input Level TTL Compatible Connector Type SMA Environmental Condition Operation Temperature -5℃ ~ 50℃ (23 ℉ ~ 122℉) Storage Temperature -20℃ ~ 70℃ (-4℉ ~ 158℉) Calibration Cycle 1 year Dimension Weight 5.0Kg (11lbs) (Include Battery) Size (W x H x D) 315x245x95mm 12.4'x9.6'x3.7' Power Supply AC Input 100 ~ 240V 2.5A, 50 ~ 60Hz General Interface Ports Serial 1 Port USB 1.1 1 Port 10Mbps LAN 1 Port GPS Antenna (SMA) 1 Port Built-in Speaker Battery (Lithium Ion) Normal Voltage 10.8V Normal Capacity 6840mA Maximum Charge Voltage 12.6V Battery Operation Hour 1.5 Hours at full charge

Product Info

  • Manufacturer : Gencomm
  • Product : RF Analyzer
  • Model : GC7106A
  • Link : none
  • Tel Service : 02-3666-6341
  • UserPrice : ₩2,000,000
  • RentalPrice : ₩340,000